Autzoo.1415 net.bugs.v7 utcsrgv!utzoo!henry Mon Feb 22 21:34:08 1982 versatec plot software The documentation in plot(5) lies about the "natural" space() setting of the Versatec. The Versatec filter appears to have been crudely converted for use with fanfold paper, with the result that the size of the plot space is constrained by the 8.5-inch height of Versatec fanfold sheets (and the Versatec's unwillingness to plot too close to the folds). The true space() specification for the Versatec is: space(0, 0, 1536, 1536) Since sensible installations generally use roll paper, the filter should be modified appropriately. This shouldn't be hard but I haven't tried it yet.